ENGINEERED STEAM SOLUTIONS

Y Type Strainer

Y type strainers for steam, air, oil or water piping, protect equipment, steam traps, valves etc. from dirt, rust or scale, and debris, in the pipeline. All strainers have a large flow area around the screen, to reduce pressure drop, and the screens have a flow area of 3 times.

Features

  • Simple yet sound construction ensures long service life. A stainless-steel strainer screen with a large surface area ensures minimum pressure drop and requires less frequent cleaning. Designed for easy in-line cleaning and maintenance.
  • Y type strainer is designed to remove solid particles 
  • Y type strainer is reduced levels of contamination

Installation

For horizontal installations, y type strainer should be installed with the screen in the horizontal plane or below the centre-line of the pipe. Ensure accessibility of the strainer cap for cleaning.

Maintenance

This product can be maintained inline without disturbing the piping connections, provided isolation valves are fitted before and after the trap. Ensure that the trap is isolated – upstream and downstream – before attempting to dismantle it.

NO. PART MATERIAL QTY.
1. Body ASTM A216 WCB 01
2. Cover ASTM A216 WCB 01
3. Strainer Screen AISI 304 (40 MESH) 01
4. Gasket Sprial wound SS304 with Graphite Filler
5. Stud/Nut ASTM A193 Gr. B7/2H

* CF8, CF8M on request

Available Spares

  • Strainer Screen
  • Gaskets

Advantages

  •  Long service life
  • Easy to install
  • Easy to dismantle and clean

USE

Y type strainers are used in pipelines to protect pumps, meters, control valves, steam traps, regulators and other process equipment.

Product Range (Y Type Stariner):

MODEL SIZE MATERIAL. END CONNECTIONS PMA / TMA
PS11 DN15 ~ DN 50 Cast Iron  Screwed (BSP, BSPT,NPT), SW 40/220
A216 Gr. WCB,

A351 Gr. CF8

Screwed (BSP, BSPT,NPT), SW 40/340
DN65 ~ DN 200 A216 Gr. WCB FL #150, #300 #150 – 13/220

#300 – 28.8/425

Menu